Equipment Dispatch - 1 (403) 596-6801 ···· Sales - 1 (403) 877-0589

Welcome

There's much to see here. So, take your time, look around, and learn all there is to know about us. We hope you enjoy our site and take a moment to drop us a line.

Boilers

1 x 50 HP

- Diesel fired

- Tri Axle goodneck trailer


4 x 100 HP

-  3 Diesel fired and 1 Tri fuel

- Skidded


2 x 125 HP

- Tri fuel

- Skidded


5 x 200 HP

- Tri fuel

- Skidded


1 x 300 HP

- Tri fuel

- Skidded

Additional Information

Our 50 HP and 60 HP mobile units have built in generators.

Our Skidded equipment comes fully self contained with built in light towers, generators as well as built in heat exchangers.

Frac heating water services

12,000,000 BTU Line Heater / 358 HP Output

Hi-R Temp Frac Water Heater Fuel Consumption:

- Diesel Consumption: 396 liters / hour

- Natural Gas Consumption: 15,000 SCFH/12-15 MCF

- Propane Consumption: 6000 SCFH= approximately 163 gal / hour

- Fuel Supplied by Customer

Technical Data:

- The unit output is 12,000,000 BTU / hour (358 horsepower)

- Line Phase Heater increases the temperature of the oil and the oil heats the water in the exchanger

- Example: 4 m3 / minute of water incoming at 3° will rise to 15° in outgoing temperature

Flow Rates as Follows:

- 1 m3/50°C Rise in Water Temp

- 2 m3/25°C Rise in Water Temp

- 3 m3/16°C Rise in Water Temp

- 4 m3/12°C Rise in Water Temp

- 5 m3/10°C Rise in Water Temp

- 6 m3/8°C Rise in Water Temp

- 7 m3/7°C Rise in Water Temp

- 8 m3/6°C Rise in Water Temp

Other Information

- Complete with 100 KVA Genset and 4000 Watt Light

- Heat Exchanger inlet/outlets are 12" 150 ANSI Flanges

18,000,000 BTU / 538 HP Output

Hi-R Temp Frac Water Heater Fuel Consumption:

- Diesel Consumption: 600 liters / hours

- Natural Gas Consumption: 23,500 SCFH / 18-22 MCF

- Propane Consumption: 11,750 SCFH

- Fuel Supplied by Customer

Technical Data:

- The unit output is 18,000,000 BTU / hour (538 horsepower)

- Line Phase Heater increases the temperature of the oil and the oil heats the water in the exchanger

- Example: 4 m3 / minute of water incoming at 3° will rise to 21° in outgoing temperature

Flow Rates as Follows:

- 1 m3/75°C Rise in Water Temp

- 2 m3/37°C Rise in Water Temp

- 3 m3/25°C Rise in Water Temp

- 4 m3/18°C Rise in Water Temp

- 5 m3/15°C Rise in Water Temp

- 6 m3/12°C Rise in Water Temp

- 7 m3/10°C Rise in Water Temp

- 8 m3/9°C Rise in Water Temp

- 9 m3/8°C Rise in Water Temp

Other Information

- Complete with 100 KVA Genset and 4000 Watt Light

- Heat Exchanger inlet/outlets are 12" 150 ANSI Flanges